D1 / D2 / D3 kVA online UPS (100–127 V output)

Online UPS units designed for non-220 V sites. Order the wrong voltage variant and the equipment simply cannot be plugged in.

THTAK D1 / D2 / D3 kVA product photo Product photo
Appearance for reference only; actual specification and accessories follow the quotation.
Type
Online double-conversion (low-voltage output)
Typical use
110 V / 120 V sites, overseas project fit-outs
Models covered
D1KVA (1 kVA), D2KVA (2 kVA), D3KVA (3 kVA)
Category
UPS systems / THTAK — our own product line

The voltage nobody checks until delivery

Low-voltage sites are rarer in Hong Kong than overseas — which is exactly why orders go wrong: the UPS is specified, delivered, and only at installation does someone read the equipment label. We ask for the equipment voltage at quotation stage for precisely this reason.

Because the D1 line is built in our own factory, the output voltage is a build parameter: 100, 110, 120 or 127 V, set at order and verified on the test sheet. Lead times are short since the platform is standard.

Key features

  • Selectable output 100 / 110 / 120 / 127 V for low-voltage distribution
  • Online double-conversion — output isolated from the mains
  • Pure sine wave, suitable for modern electronic supplies
  • Rack or tower mounting (by model)
  • Made for sites wired to 110 V / 120 V standards and overseas projects

Where it fits

110 V / 120 V premises

The site itself runs low-voltage distribution and needs a UPS that matches.

Overseas projects

The destination country runs a low-voltage standard — configure to the local voltage.

Special equipment

Some imported equipment specifies 100 V or 110 V supplies and needs a matching UPS.

Frequently asked questions

Why is this even a separate product?
Because nearly every UPS sold in Hong Kong outputs 220–240 V. Equipment from Japan, Taiwan or the Americas expecting 100–127 V cannot be powered from it — and a step-down transformer on the output wastes budget and adds a failure point. The D1 series outputs the low voltage natively.
Can it run from 220 V mains?
Yes — the input accepts the local supply; the output is set to the low voltage your equipment needs. Tell us the site voltage and the equipment voltage at enquiry and we configure accordingly.

Related models & accessories

Specifications

Capacity1–3 kVA (by model)
ArchitectureOnline double-conversion
Output voltage100 / 110 / 120 / 127 V (by model and setting)
Output waveformPure sine wave
Form factorTower or rack (by model)
RuntimeSized to load and battery configuration
Typical sitesLow-voltage premises, overseas projects, special equipment

Specifications follow the manufacturer's latest data. Actual configuration must be sized against the site load, required runtime and distribution environment — this table is for selection reference only.