EATON Power Xpert 9395 (200–1200 kVA)

The workhorse of data centres and large facilities: a 200–1200 kVA modular platform whose sixth-generation IGBT rectifier takes input power factor to 0.99.

EATON Power Xpert 9395 series product photo Product photo
Appearance for reference only; actual specification and accessories follow the quotation.
Brand
EATON
Type
Three-phase high-power modular online double-conversion
Typical use
Data centres, communications hubs, hospitals, large offices
Models covered
Power Xpert 9395 200–1200 kVA
Category
UPS systems / EATON

Where the 9395 sits in Eaton's high-power line

Model Power band Character
93T 15–200 kVA Mid-size rooms, transformerless high-efficiency design
93PR 25–1200 kW Modular, phased expansion
Power Xpert 9395 200–1200 kVA Military-grade platform, modular redundancy

Two design details that save money

  • Easy Load testing without a load bank — conventional acceptance testing hires resistive load banks for a full-load run. The 9395 feeds the energy back to the supply side instead, saving the hire cost and the space.
  • Hot-sync paralleling — paralleling needs no extra parallel board or cable logic. Units synchronise without wires between them, which removes a single point of failure and makes expansion simple.

Where it fits

  • Main machine-room supply for enterprise and colocation data centres
  • Communications hubs, where harmonic performance and generator compatibility are sensitive
  • Healthcare — operating theatres, imaging and other loads that cannot go dark

Large projects take a long time from selection to commissioning. Start the site survey and scheme design early.

Key features

  • 200–1200 kVA, modular, so upgrading, parallel redundancy and maintenance are all straightforward
  • Sixth-generation IGBT rectifier: input power factor up to 0.99 with low harmonic disturbance
  • Hot-sync parallel technology — synchronising, load sharing and selective tripping with no parallel board
  • Easy Load testing: full-load testing without hiring a resistive load bank
  • ESS energy-saving mode for higher conversion efficiency
  • ABM battery management extends battery life
  • Mains-friendly design with no reflected pollution, and good generator compatibility

Related models & accessories

Specifications

Power rating200–1200 kVA
ArchitectureModular online double-conversion
Rated voltage380 / 400 / 415 VAC
Frequency50/60 Hz
RectifierSixth-generation IGBT, input power factor 0.99
ConfigurationScalable

Specifications follow the manufacturer's latest data. Actual configuration must be sized against the site load, required runtime and distribution environment — this table is for selection reference only.