EATON 93T three-phase online UPS

Backbone power protection from machine rooms to production lines. At this level the UPS is the easy part — the design work is in distribution, cooling and runtime.

EATON 93T series product photo Product photo
Appearance for reference only; actual specification and accessories follow the quotation.
Brand
EATON
Type
Three-phase online double-conversion (high power)
Typical use
Data centres, large machine rooms, industrial lines
Models covered
EATON 93T 15kVA, EATON 93T 20kVA, EATON 93T 30kVA, EATON 93T 40kVA, EATON 93T 60kVA, EATON 93T 80kVA, EATON 93T 100–200kVA
Category
UPS systems / EATON

What changes at three-phase scale

Above roughly 20 kVA, the conversation stops being about a box and becomes about a room: input switchgear, output distribution, battery string sizing and its floor loading, heat rejection, and a maintenance regime. We quote the whole system, and the sizing is done against a measured load — never against the UPS nameplate.

Internal batteries or a battery room?

The 15–80 kVA frames can carry enough internal battery for about five minutes at full load — often exactly enough to bridge to a generator. Longer runtimes need an external string, which changes the floor-loading and ventilation plan. We size both options side by side at survey.

Key features

  • Three-phase online double-conversion, transformerless, modular tower build
  • 15–200 kVA with 1.0 output power factor — 100% of the rating is usable
  • Three-level topology: >96% efficiency at typical load; >99% in ESS eco mode
  • ABM intelligent battery management extends battery life by 50%+
  • Hot-sync wireless paralleling — no paralleling board, redundancy and expansion without a single point of failure
  • 15–80 kVA models accept internal batteries (5 minutes at full load) without extra footprint
  • DC capacitor health monitoring with early warning
  • Module-level serviceability keeps MTTR low
  • Charger power up to 70% of rating — matches large VRLA or lithium strings

Where it fits

Data centres and large machine rooms

Backbone protection where redundancy and maintainability matter more than the unit's badge.

Industrial line backbone

Whole-line power quality — a voltage sag can scrap a batch and shift calibration.

Telecoms and critical infrastructure

Continuous-duty sites that need monitoring and a scheduled maintenance plan from day one.

Frequently asked questions

What is hot-sync paralleling?
Two or more 93T units can share a load and provide redundancy without a paralleling cabinet or control wiring between them — each unit synchronises itself. It removes the paralleling system as a single point of failure and lets you add capacity by adding a unit.
What does the project actually involve?
At this scale the UPS is typically a quarter of the job: input distribution, output boards, battery room or cabinet, cooling, floor loading, monitoring and a commissioning test. We scope all of it at survey stage, not after delivery.

Related models & accessories

Specifications

Capacity15 / 20 / 30 / 40 / 60 / 80 / 100 / 120 / 160 / 200 kVA
ArchitectureOnline double-conversion, transformerless, modular tower
Input voltage380 / 400 / 415 Vac adjustable
Frequency50 / 60 Hz
Output power factor1.0 @ 40 °C
Efficiency>96% online; >99% in ESS mode
RedundancyHot-sync paralleling (N+1 and similar)
RuntimeSized to battery string and load; 15–80 kVA can house batteries internally (5 min full load)

Specifications follow the manufacturer's latest data. Actual configuration must be sized against the site load, required runtime and distribution environment — this table is for selection reference only.

Specification sheets follow the latest manufacturer revision. For other technical documents, ask us and we will send them over.