EATON 93TX three-phase UPS (15–80 kVA)
The hard-wearing member of the 93 series: output isolation transformer and IP21 protection as standard, designed for dusty industrial sites and poor-quality grids.
Product photo
- Brand
- EATON
- Type
- Three-phase online double-conversion (with output isolation transformer)
- Typical use
- Industrial sites, mid machine rooms, poor-grid environments
- Models covered
- EATON 93TX 15kVA, EATON 93TX 20kVA, EATON 93TX 30kVA, EATON 93TX 40kVA, EATON 93TX 60kVA, EATON 93TX 80kVA
- Category
- UPS systems / EATON
Built for the sites that kill ordinary UPS units
Dust on boards, humid air, a grid that sags every time the lift starts — none of these are exotic in Hong Kong's industrial buildings. The 93TX answers them with hardware rather than a service contract: coated boards, washable filters, an isolation transformer, and monitoring that warns before capacitors reach end of life.
When we specify it
Roughly: if the room has no air-conditioning, or the supply feeds motors and welders on the same riser, the TX is the default. We confirm with a site survey — the state of the existing distribution tells us more than the specification sheet does.
Key features
- High-insulation output isolation transformer standard — isolates mains disturbance from the load and load harmonics from the inverter
- IP21 enclosure, conformally coated circuit boards, washable dust filters included
- IGBT rectification with full digital DSP control
- Battery contactor standard — disconnects the DC system automatically on abnormality to protect the batteries
- Monitors capacitor and key-component temperatures for life prediction and service prompts
- Redundant power-module fans — a single fan failure still supports 70% load
- Dummy-load test function verifies power devices and battery strings online
- 15–30 kVA can take an internal input isolation transformer (40 kVA and up use a separate transformer cabinet)
Frequently asked questions
93T or 93TX — how do I choose?
What does the output isolation transformer actually do?
Related models & accessories
EATON 93T series
Backbone power protection from machine rooms to production lines. At this level the UPS is the easy part — the design work is in distribution, cooling and runtime.
View detailsEATON 9EHD 2.0
Built for hostile industrial environments: IP42 protection, isolated airflow, coated boards — power assurance for workshops, petrochemical and metallurgy sites.
View detailsIndustrial production lines and manufacturing
One second of lost power on a production line can cost a whole batch of work in progress. On a factory floor, backup power is really about inrush current and voltage quality, not just capacity.
View detailsSpecifications
| Power ratings | 15 / 20 / 30 / 40 / 60 / 80 kVA |
|---|---|
| Architecture | Online double-conversion with output isolation transformer, modular tower |
| Input voltage | 380 / 400 / 415 Vac adjustable |
| Frequency | 50/60 Hz |
| Inverter overload | 10 minutes at 125% load |
| Protection rating | IP21 |
Specifications follow the manufacturer's latest data. Actual configuration must be sized against the site load, required runtime and distribution environment — this table is for selection reference only.
Specification sheets follow the latest manufacturer revision. For other technical documents, ask us and we will send them over.