EATON 9PX lithium UPS (1–3 kVA)
The 9PX's online double-conversion architecture with LiFePO4 batteries — battery life stretches from 3–5 years to 8–10, so the unit may never need a battery change.
Product photo
- Brand
- EATON
- Type
- Online double-conversion (lithium built in)
- Typical use
- Edge rooms, unmanned sites, hot environments
- Models covered
- 9PX1000IRT2U-L, 9PX1500IRT2U-L, 9PX2200IRT2U-L, 9PX3000IRT2U-L, 9PXEBM48RT1U-L (expansion battery), 9PXEBM72RT1U-L (expansion battery)
- Category
- UPS systems / EATON
Who actually needs this
The lithium 9PX is not a status purchase — it solves a specific maintenance problem: batteries in places people rarely visit. An edge room on a rooftop, a cabinet in a factory, a site served by a two-hour round trip — each battery replacement is a project. A unit whose batteries outlast the unit itself removes that entire category of work.
What UL1973 means here
It is the safety standard for stationary battery systems — covering the cells and their integration. Combined with the BMS (over-charge, over-discharge, thermal protection), it is the certification you want when lithium goes into a building's equipment room.
Key features
- Lithium battery life two to three times that of lead-acid — 8–10 years in service
- 80–120% more runtime in the same volume
- LiFePO4 cells with a battery management system, UL1973 certified
- Lithium built into the 2U chassis — no separate battery cabinet
- Efficiency meets Energy Star requirements
- Pairs with a network card (UL/IEC security certified) and IPM software for virtualisation shutdown
Frequently asked questions
Is the lithium premium worth it?
Can I mix lithium and lead-acid units in the same room?
Related models & accessories
EATON 9PX series
The mainstream choice for server rooms: online double-conversion keeps the output fully isolated from the mains, with efficiency and serviceability at practical levels.
View detailsEATON 9PX Marine series
A shore UPS dropped onto a vessel does not survive salt spray, motion and heat. The 9PX Marine is DNV-GL type approved and reworked for the marine environment.
View detailsUPS Battery Replacement
Batteries are the wearing part of every UPS. We replace them on schedule — not after the alarm.
View detailsSpecifications
| Capacity | 1–3 kVA |
|---|---|
| Architecture | Online double-conversion |
| Battery type | LiFePO4, UL1973 certified |
| Rated output voltage | 200/208/220/230/240 V |
| Rated output frequency | 50/60 Hz |
| Form factor | Rack or tower, 2U |
Specifications follow the manufacturer's latest data. Actual configuration must be sized against the site load, required runtime and distribution environment — this table is for selection reference only.